| İlan No: | #00206168 |
| Kategori: | Yangın Hidrantı |
| Marka: | Has Arı |
| Ürün Tipi: | Satılık |
| Ürün Durumu: | Sıfır - Yeni |
| Menşei: | Türkiye |
| Konum: | Üniversite Mah. / Avcılar / İstanbul |
| Garanti Durumu: | 2 Yıl Garantili |
| Satış Detayı: | Havale / EFT, Görüşülür |
| Teslim Durumu: | Stokta Var |
ARTICLE 95- (1) In the protection of buildings from fire, in order to be able to intervene from outside to fires that cannot be extinguished in the first response, the hydrants to be installed within the hydrant system to be established to cover the entire perimeter of the building or the building should be arranged in such a way that the fire brigade and vehicles can easily approach and connect. (2) The design flow rate of the hydrant system must be at least 1900 l/min. The flow rate is increased according to the danger class of the building. There should be 700 kPa pressure at the hydrant outlet. (3) The distance between hydrants is 50 m in high-risk areas, 100 m in risky areas, and in medium-risk areas. 125 m and 150 m in low risk areas. (4) Under normal conditions, hydrants are placed at an average distance of 5 to 15 m from the protected buildings. (5) If there is no ring system in the pipe equipment that supplies the water to the hydrant system, the diameter of the minimum pipe that can be used should be 100 mm and it should be determined according to the hydraulic calculation. (6) The hydrants to be used in the system must be above-ground fire hydrants in accordance with the relevant Turkish Standards. In the hydrant system, underground or above-ground or both underground and above-ground line shut-off valves are provided and installed at appropriate points and places that will facilitate hydrant renewal and maintenance. (7) (Amendment: 09/09/2009 – 27344 RG / 34 art.) Building an external hydrant system in case the total floor area of the buildings to be built in the settlement areas, which have all kinds of usage areas and are planned separately from the general settlement areas, is greater than 5000 m2. it is mandatory. 47/87 (8) Municipalities with settlements where vehicles in service in their areas of responsibility cannot enter or maneuver and where there is no means of transportation, fire pools of sufficient capacity equipped with above-ground fire hydrants or pumps in suitable places of these settlements in order to effectively respond to fires that may occur in these settlements, and cisterns have to be built.Has Arı
Above Ground Fire Hydrant
Makinaturkiye.com İade Politikası
Makinaturkiye.com üzerinden yapılan satın alma işlemleri, müşteri memnuniyetini ön planda tutan güvenli bir alışveriş deneyimi sunmaktadır. Satın alma butonu, doğrudan ödeme işlemi gerçekleştirmek yerine bir satın alma formu oluşturarak satıcı firma ile alıcıyı bir araya getirmektedir. Bu süreçte, ürün iadeleri Türkiye Tüketici Hakları Yönetmeliği kapsamında değerlendirilmektedir ve belirlenen yasal çerçevede işlem görmektedir.
İade Süresi:
İade Edilebilecek Ürünler:
İade İşlemi Nasıl Yapılır?
İade Sonrası Geri Ödeme Süreci:
İade Edilemeyen Ürünler:
Cayma Hakkı:
Ayıplı Ürün İadesi:
Makinaturkiye.com platformu, alıcı ve satıcı arasında köprü görevi görmektedir. İade süreçleriyle ilgili detaylı bilgi almak veya talep oluşturmak için satın alma formu üzerinden satıcı firma ile doğrudan iletişime geçebilirsiniz.
| Ülke | Para Birimi | En Düşük Kargo Fiyatı | En Yüksek Kargo Fiyatı |
|---|